Ando AQ7155 Mini Handheld OTDR 1.31& 1.55 UM Singlemode

•Wavelength 1.31 µm / 1.55 µm
•Distance range 5 km, 10 km, 20 km, 40 km, 80 km
•Detection measurement range 18 / 16 dB
•Dynamic Range (typical) 23 / 22 dB
•Dead zone Less than 10 m, Typical 7 m (reflective)
•Less than 50 m , Typical 30 m (backscatter)
•Distance resolution 1 m (5, 10 km range)
•Measurement time Approx. 20 sec. (5 km range), Approx. 90 Sec. (40 km range)
•Display LCD (backlit)

Artikelnummer: 1655 Kategorien: ,

Beschreibung

The Ando AQ-7155 Mini-OTDR is 1/5 the size and weight of our existing full-size OTDR units. Measurement can be performed by the press of a single button. Battery operation allows the unit to be used in the field. Data can be stored on an PCMCIA memory card. The data on the memory card can be analyzed on an IBM-compatible personal computer using emulation software (which is sold separately). SET UP conditions, data lists and measured traces can be printed out.

•Small size and light weight
•Simple Operation
•Battery operation
•Convenient memory function
•Data Print-Out

Zusätzliche Informationen

Hersteller

Kategorien