Com-Power FCLCE-1000 Current Clamp Calibration Fixture for CLCE-400

CAL FIXTURE FCLCE-1000:
•Dimension (A): 40 mm
•Dimension (B): 132 mm
•Dimension (C): 130 mm
•Dimension (D): 23.25 mm
•Dimension (E): 22.6 mm
•Dimension (F): 16.1 mm
•Dimension(G): 170 mm

Artikelnummer: 0237 Kategorien: ,

Beschreibung

Discontinued replaced by FCLCE-1032. The Com-Power’s Current Probe and Bulk Current Injection (BCI) Probe Calibration Fixtures are each designed to accomodate the exact physical dimensions and electrical properties of the respective probe with which it is intended to be used. With the appropriate probe installed, a nominal 50 ohm transmission line impedance is maintained across the frequency range of the probe. Calibration fixtures are used for calibration of Coupling Loss/Transfer Impedance of current probes and BCI probes, as well as for the calibration of test levels for conducted immunity/susceptibility tests using BCI probes.
The Com-Power FCLCE-1000 Calibration Fixture is designed for use with the Com-Power CLCE-400. The fixture is required for calibration of the Transfer impedance, insertion loss & VSWR parameters.

•Maintains 50 ohm Nominal Impedance Transmission Line with Probe Installed
•Coupling Loss/Transfer Impedance Calibration
•Test Level Calibration of Bulk Current Injection Probes
•Three-Year Warranty

 

Zusätzliche Informationen

Hersteller

Kategorien

Com-Power FCLCE-1000       Current Clamp Calibration Fixture for CLCE-400  

Com-Power FCLCE-1000 Produktdatenblatt

 


echo do_shortcode('[google-translator]');