Com-Power LI-3P-4100 10kHz – 10MHz LISN – Three phase, 50 uH, 100 Amps, Mil-Std 461

10.070,00 

•Standards: MIL-STD-461D/E/F/G
•Type: 50Ω, 50 μH, (4) Conductor Network
•Frequency Range: 10 kHz to 10 MHz
•Insertion Loss – 10 kHz to 150 kHz: <6 to <0.5 dB (decreasing linearly with the logarithm of frequency)
•Insertion Loss – 150 kHz to 30 MHz: <0.5 dB
•Isolation – 10 kHz to 200 kHz: >10 to >20 dB (increasing linearly with the logarithm of frequency)
•Isolation – 200 kHz to 2 MHz: >20 to >35 dB (increasing linearly with the logarithm of frequency)
•Isolation – 2 MHz to 10 MHz: >35 dB
•Current (maximum continuous, perline): 100 Amperes
•AC Voltage (maximum): 500 Voltsrms (line to line), 288 Voltsrms (line to ground); 50 to 400 Hz
•DC Voltage (maximum): 705 Volts DC
•Weight: 59.1 lbs. (26.8 kg)

Artikelnummer: 0286 Kategorien: ,

Beschreibung

The Com-Power LI-3P-4x Series consists of four separate models of four-conductor, 50Ω, 50 μH Line Impedance Stabilization Networks (LISNs). The primary differences between the four models are their respective current ratings:
LI-3P-416 16 Amps (per line, continuous)
LI-3P-432 32 Amps (per line, continuous)
LI-3P-463 63 Amps (per line, continuous)
LI-3P-4100 100 Amps (per line, continuous)
These LISNs provide the necessary measurement platform for performing power line conducted emissions compliance testing per MIL-STD-461, CE102, conducted emissions, radio frequency potential, power leads. The LISNs perform the following functions:
•provide a defined, stable power line impedance across its frequency range for the Equipment Under Test (EUT);
•isolate the EUT and measurement circuit from the power source, thereby minimizing its influence on the measurements; and,
•couple the disturbance voltages to the coaxial measurement port, which connects to the measuring instrument.
The LISNs use air-core inductors to prevent saturation and permeability variation. The mounting plates are left unpainted in order to facilitate connection to earth ground in their installation, which is essential due to high leakage currents. The side panels for each LISN are louvered for cooling purposes. The LI-3P-463 and LI-3P-4100 also include two internal cooling fans operated by a switch on the rear panel.

•Remote Switching of Line Under Test
•Four-conductor, 50Ω , 50 μH, Network appropriate for 3Ø Delta and Wye Power Configurations
•Three-Year Warranty

Zusätzliche Informationen

Hersteller

Kategorien

Com-Power LI-3P-4100          10kHz – 10MHz LISN – Three phase, 50 uH, 100 Amps, Mil-Std 461                

Com-Power LI-3P-4100 Produktdatenblatt